EDKR(AT)315M8 AND
Asynchronous EDKR motors(AT)315M8 VA are designed to work from an alternating current network with a frequency of 50 Hz with isolated neutral of coal mines and mines, dangerous due to the content of mine gas (methane) and (or) coal dust as a drive for stationary machines and mechanisms (pumps, fans, compressors), as well as drives of other mechanisms and machines with similar modes of operation. Nominal values of the main engine parameters in the S1 mode according to DSTU IES 60034-1 are given in the table.
Nominal values of the main engine parameters in the S1 mode according to DSTU IES 60034-1 are given in the table.
The stator winding can be made of a rigid copper busbar, rotor – aluminum or copper-brass casting.
It is allowed to operate engines in mode S2 = 60 min, S3, S4 – 60% with the inertia factor F = 2 and frequency of inclusions to 30 included per hour, at the same time, the permissible power value is no more, specified for modef S1.
Explosion protection level of engines "explosion-proof" with types of explosion protection "explosion-proof shell" and "intrinsically safe electrical circuit" RV Ex d ia I Mb.
The degree of protection of motors and input boxes is IR54, external fan IR20 according to GOST 17494.2.6 (Jesus 60529).
Type of climatic execution of engines – U2.5 according to GOST 15150.
Execution of engines according to the method of installation - IM1001(V3), IM2001(V35) (foot/flange), IM3001(V5) (flange) according to GOST 2479, DSTU EN 60034-7:2019.
Method of cooling engines – IS141 according to DSTU EN 60034-6:2015.
MAIN TECHNICAL INDICATORS
Engine parameters | Value | |
Capacity, kW | 110 | |
Rotational frequency, rpm | 740 | |
Nominal voltage, AT | 380/660 | 660/1140 |
Nominal current, A | 217/125 | 125/72,5 |
efficiency, % | 94 | |
Power factor, cosφ | 0,82 | |
Nominal moment, Nm | 1420 | |
Mpusk/Mnom | 2,2 | |
Mmah/Mnom | 2,3 | |
Admission/Inom | 6,4 | |
Insulation class | N | |
Mass, kg | 1380 |